TERRA-P
Purpose of use
- Measurement of gamma radiation equivalent dose rate.
- Measurement of gamma radiation equivalent dose.
- Evaluation of surface contamination by beta radionuclides.
- Clock, alarm clock.
Household aplication
- Apartment, building and construction control; personal radiation safety; ground-surface continuous territories control; and vehicles control.
- Evaluation of radiation contamination of farm products.
- Visual aids for educational institutions.
Features
- Three independent measuring channels with alternate indication of data on the single liquid crystal display.
- Built-in gamma, beta sensitive Geiger-Muller counter.
- Automatic setting of measurement intervals and ranges.
- Audio signalling of each detected gamma-quantum and beta-particle.
- Programming of audio alarm threshold level relative to gamma radiation dose rate.
- Digital display.
- Two AAA size batteries.
- Four-level indication of battery discharge.
- Shock resistant frame.
- Small weight and dimension parameters.
Specifications
Measurement ranges and basic relative errors:
- Gamma radiation equivalent dose rate (137Cs) µSv/h 0,1...999,9; ±25%
- Gamma radiation equivalent dose (137Cs) mSv 0,001...9 999; ±25%
- Beta-particles flux density with possible evaluation of surface contamination by beta radionuclides (90Sr+90Y) 1/(cm2-min) 10...100 000;
Energy ranges of measurement and energy dependence:
- Gamma radiation MeV 0,05...3,0; ±25%
- Beta radiation MeV 0,5...3,0;
- Measurement time intervals seconds 5...70
- Battery life hours 6 000
- Operating temperature range oC -10...±50
- Weight kg 0,15
- Dimensions mm 120x52x26